Cistermiser urinal controls address a common commercial-water problem: older automatic cisterns can flush on a timer whether or not anyone has used the urinal. The result is avoidable consumption overnight, at weekends and during low-occupancy periods. The practical remedy is not a behaviour poster alone. Facilities teams should first prove what the meter is recording, then match the washroom with an individual post-use control, a room or group occupancy control, a revised timer strategy or, where suitable, a waterless system.
Published results show why the diagnosis matters. A Thames Water business guide describes a seven-urinal office whose consumption stayed constant every day because the urinals flushed at regular intervals. Its example reports a 75% reduction after PIR controls. Those figures are site-specific and based on historical prices, so a current decision should use your own baseline, occupancy schedule and combined water-and-sewer tariff.
As an Amazon Associate I earn from qualifying purchases.
The Tool Desk
Outbyte Driver Updater FREEScan for outdated or missing drivers - takes under a minuteDriver Scan →Outbyte PC Repair FREEClear out junk files and repair common Windows errorsFree Scan →Why do urinals flush when nobody uses them?
In a conventional automatic cistern, a solenoid or valve is often driven by a clock. The cistern fills and discharges at set intervals regardless of whether a user has entered the washroom. A quiet building therefore receives the same flush pattern as a busy one unless someone changes the schedule manually.
This creates two distinct problems. First, water is consumed when there is no corresponding use. Second, the timer can be wrong in both directions: it may over-flush during nights, weekends and shutdowns, yet under-flush during busy periods. The University of Surrey’s peer-reviewed study of delayed-action PIR controls explicitly notes that timer controls do not account for use and can overuse water in quiet periods or under-flush when demand rises (Sustainability, 2022).
Popular on Amazon
- Ergonomically Designed: Work in tight areas with a compact design that gets into tough spots
- Both tools are designed to fit into difficult to reach spaces
- Complete a wide range of applications with a high-performance motor that delivers up to 300 UWO, and an impact driver delivering up to 1,400 in-lbs of torque
- Both the DEWALT impact driver and drill driver feature integrated LED work lights with a convenient 20-second delay, ensuring enhanced visibility in dimly lit or challenging work areas
- One-Handed Loading - Keep one hand free with a 1/4 in. hex chuck that accepts 1 in. bit tips
The first sign is often a meter trace rather than a complaint. If the building is unoccupied but the water meter shows a regular, repeating demand, isolate urinal services and compare the pattern. A seven-urinal office in Thames Water’s guidance used water at a constant rate every day; the regularity pointed to timed flushing rather than occupancy.
How much water can an uncontrolled urinal use?
There is no universal saving percentage because flush frequency, cistern volume, pressure, occupancy and tariff differ. The published examples below show the range of outcomes and the assumptions behind them.
| Source and setting | Reported result | Qualification |
|---|---|---|
| Thames Water, seven-urinal office | 75% reduction in urinal-attributed consumption and approximately £3,800 annual saving | Circa-2015 guidance; cost is historical and site-specific |
| Thames Water worked example | 315 m³/year and £652 unmanaged versus 36 m³/year and just under £75 after reducing flushing | Assumes four flushes per hour, 24 hours a day and 2014 prices |
| Thames Water data reported by CIPHE | Average saving of 965 litres per day from fixing uncontrolled urinals | 1,761 business visits in 2023/24; data is attributed to Thames Water |
| University of Surrey campus programme | 32,525,000 litres per year reported as prevented waste, just over £50,000 in combined charges and average 140-day return on investment | Aggregate university results, including pandemic-era occupancy changes; not a typical single-building forecast |
Prices checked November 2026.
Use these numbers as evidence that uncontrolled flushing can be material, not as a promise for your project. Calculate your own opportunity from measured night-time flow and the current combined supply and sewer charge.
Which urinal control strategy fits a commercial building?
The right choice depends on the existing plumbing, occupancy pattern, hygiene requirements, installation access and maintenance capacity. A control that is economical in a small office may be disruptive or expensive across a large venue.
| Option | How it works | Advantages | Limits and best-fit conditions |
|---|---|---|---|
| Individual PIR valve | An infrared sensor detects use at each urinal and releases a measured flush. | Flushes respond directly to demand; waste during empty periods is largely removed; settings can be tailored per unit. | Many individual units mean more installation points, wiring and maintenance. Suits washrooms where fixture-level control is accessible. |
| Room or group occupancy control | A PIR occupancy sensor manages supply or flushing for several fixtures or washroom services. | One control can cover a large group and may reduce the initial investment where there are many urinals. | It responds to room occupancy rather than each use, so configuration must avoid unnecessary flushes after brief or unrelated occupancy. Suits larger washrooms and integrated lighting or water controls. |
| Existing timer, revised | The time clock is retained but schedules are reduced or aligned with opening hours. | Lowest physical disruption where occupancy is predictable and the installation budget is limited. | It still cannot see actual use; holiday, shift and event patterns can make the schedule wrong. It is a compromise, not demand-based control. |
| Waterless urinals | Urine drains through a cartridge or seal without routine flushing water. | Can remove flush-water demand entirely. | May require remodeling, altered pipework or drainage, non-water cleaning, user-acceptance work and checks against regional legislation. It is not an automatic retrofit. |
How do individual PIR urinal controls work?
An individual PIR system senses a person at the fixture, applies a configured delay or detection rule, and opens a valve for a defined flush. Because the flush follows use, an empty washroom does not receive the same sequence as a busy one. The installation still needs a hygiene strategy for long idle periods.
Also popular on Amazon
- Valued Carpenter Pencil Set: You will get 2 pcs solid carpenter pencils with 26 piece 2.8 mm refills, 1 replaceable sharpener, 1 plastic storage box.The complete carpenter pencils combination allows you to finish your work faster and more easily
- Deep Hole Marker Pencil: The deep-hole construction pencils adopts 45mm elongated tip design, which is more convenient to mark in the small hole or in other tight areas that other carpenter markers cannot reach
- Carpenter Pencils with Sharpener: The sharpener is screwed into the top of the work pencil, which won't get lost either. Built-in pencil sharpener that keep the lead with pointed and smooth to Improves line of sight in fine work
- Stronger Solid Lead: This work pencil is matched with a 2.8 mm thick lead , which is much thicker and stronger during the drawing process of construction work, it will not break or damage easily
- Marks on Various Surfaces: 3 colors solid construction pencil can marks on various surfaces,such as metal, plastic, wood, paper etc. Ideals for woodworkers, contractors, craftsmen, builders, merchants and masons
Cistermiser’s Direct Flush is a named example. Its specification catalogue says the valve can flush with 0.5 litres after use, but that is a product specification rather than a guaranteed saving for every bowl, pressure or installation. The catalogue also models 134,280 litres per year and £400.16 of annual cost saving against a stated uncontrolled profile, using £2.98 per cubic metre for typical UK domestic combined supply and sewerage in February 2018. Those assumptions are not current tariff quotes.
Do these 3 things before closing this tab:
1Fix the driver behind crashes, sound loss and screen glitches2Clear out junk files and repair common Windows errors3Scan for outdated or missing drivers - takes under a minuteA Cambridge Assessment case study describes 96 Direct Flush Discreet valves with configurable detection and flush settings, a periodic hygiene flush and a cleaner’s mode. Cistermiser technical director David Meacock said: “Direct Flush removes the need for an auto-flush cistern and associated plumbing used in traditional urinal installations, which flush all urinals intermittently even if they have not all been used.” The case study’s installation contractor, Allied Mechanical Services, described the units and multi-product power supplies as “quick and easy to fit”; that is a project statement, not a universal installation guarantee.
When is a room-level or group control better?
A group control can be sensible when a washroom has many urinals, shared service routes or other equipment that can use the same occupancy signal. Cistermiser’s National Exhibition Centre case describes Sensazone PIR controls for water and lighting, selected because fitting separate controls to a high number of individual units would have required significant initial investment.
Group control should be commissioned around the real operating pattern. A sensor that keeps services active for a long timeout can recreate waste, while a timeout that is too short may conflict with hygiene or user expectations. Ask the installer to document detection zones, timeout, minimum and maximum flush settings, manual override and what happens during a sensor or power fault.
How should a facilities team audit uncontrolled flushing?
Start with evidence before selecting hardware. The following sequence works for offices, schools, factories, venues and construction compounds with permanent washrooms.
What’s actually slowing this PC down?
Pick the symptom - the matching free tool is one click away.
Also popular on Amazon
- 【Great Compatibility】This Katerk 1/4 inch hex shank bit holder is specifically designed for 1/4 inch hex shank drill bits. It's compatible with most 1/4 fast hex handles, hex sockets, various electric screwdrivers, and handheld screwdrivers. The bit holder makes it a valuable addition for any handyman.
- 【Secure and Safe】Built with a secure backup nut design, each drill bit holder securely locks onto your bits, ensuring they stay firmly in place. Additionally, our bit holder incorporates a high-quality steel ball rolling design that holds up to several kilograms of weight, ensuring your various drill bits don't fall off.
- 【Easy One-Handed Operation】The bit holder for impact driver allows you to change bits single-handedly, simplifying your workflow. Its multi-color design further allows for quick identification of the drill bit you need.
- 【Compact and Convenient】Thanks to its compact size, this 1/4 inch bit holder is easy to carry around. The bit holder allows for easy attachment to various tools, making this a convenient addition to your construction accessories. The Katerk bit holder is cast from high-quality alloy material, promising a long product lifespan. Despite its rugged strength, the bit holder remains lightweight, making it portable.
- 【Cool Christmas Gift For Men Stocking Stuffers】 This screwdriver bit holder, driver bit holder, impact bit holder, can be given as a gift to your loved one, especially for anyone involved in construction or electrical work. It's a must-have for stocking stuffers for men and women, tools gifts for dad, tech gadgets for men, gifts for dad, gifts for him, gifts for husband, gifts for boyfriend, cool gadgets for men, and cool gifts for dad.
- Record the baseline. Capture water-meter readings at the start and end of representative occupied and unoccupied periods. Include a night, weekend or shutdown window long enough to reveal repeating flush cycles.
- Map the plumbing. List each urinal, cistern, flush valve, isolation point, sensor and control panel. Note whether one cistern serves a group and whether other fixtures share the branch.
- Confirm the source. Temporarily isolate the urinal supply or use the documented isolation points while maintaining required hygiene controls. A regular meter signal that disappears when the urinal branch is isolated is strong evidence of uncontrolled flushing; coordinate any isolation with the responsible building-services professional.
- Document occupancy. Record opening hours, shifts, cleaning periods, events, seasonal closures and expected low-use periods. Construction and mixed-use sites often have changing crews, so a single “office hours” schedule can be misleading.
- Check hygiene requirements. Establish whether periodic hygiene flushing is required by the building’s maintenance policy, water-safety plan or installer guidance. A demand-based system must not be configured as though low use removes all hygiene obligations.
- Calculate the opportunity. Convert measured volume to cubic metres and apply the current combined water and wastewater tariff. Keep supply and sewer charges together if both are billed per cubic metre.
- Assess installation constraints. Inspect access above ceilings, electrical supplies, sensor sight lines, valve compatibility, pressure, drainage and the time available for isolation. Include making-good, permits and out-of-hours work in the project scope.
- Choose the control level. Compare individual PIR, group occupancy, revised timer and waterless options against the measured baseline, not against a generic percentage.
What hygiene and maintenance provisions are needed?
Reducing water use does not eliminate the need for appropriate washroom hygiene. Low-use buildings can require periodic flushes to keep water in the system moving, and the interval must be set with the responsible water-safety and plumbing professionals. Some product controls provide a programmable hygiene flush; the Cambridge Assessment installation is described as having one.
Include sensor lenses, valves, strainers, power supplies and isolation points in the planned maintenance schedule. Keep a record of settings so a replacement installer does not reset every unit to a factory timer. Provide a cleaner’s mode or equivalent where staff need to clean without triggering repeated flushes, and document the manual override procedure for power or sensor faults.
Are waterless urinals a better answer?
Waterless systems can remove routine flush-water use, but they shift the project toward drainage design, cleaning and user management. The Surrey study identifies potential remodeling, pipework and drainage work, non-water cleaning requirements, acceptance issues and regional-legislation considerations. Check those conditions before treating waterless urinals as a simple valve replacement.
They may suit a planned refurbishment where floors and drainage are already being altered. They are less straightforward where the building must remain open, the existing drainage arrangement is unsuitable or users are unlikely to accept the operating and cleaning regime. A controlled-flush retrofit can be less disruptive while still addressing the largest waste from empty periods.
What do published case studies actually prove?
Case studies are useful for understanding mechanisms and project choices, but they are not independent head-to-head trials. Attribute each result to its owner and preserve the site context.
Also popular on Amazon
- Toolwiz 17-inch magnetic sweeper maintaining a load capacity of up to 8.8 pounds provides a perfect solution to the problem of clearing small ferrous metal objects, such as nails, tacks, bolts, and metal shavings from workshops or garage floors.
- Convenient and portable:17” is good for home, small workshop, or small yard as it is space-saving and more reachable for narrow areas. Perfect for collecting nails or small parts in the car, under the table, and in other nooks or crannies.
- Upgraded Handle Design: The handle features a sturdy, non-telescopic design to completely prevent slipping during use. By simply adding or removing the extension poles, the height can be adjusted to 3 different lengths: 18.9" (48 cm), 32.5" (82.5 cm), and 42.5" (108 cm) from ground to top. This customizable height helps prevent back bending and muscle strain, making your cleaning tasks effortless
- Flexible wheels: Upgrade wheel screws to avoid being too tight to spin or too loose. More comfortable 3-inch rubber wheels roll smoothly on carpet, grass, concrete, and hardwood floors. Just push and pull this rolling magnet-sweeper to pick up metal nails easily.
- Lightweight materials: The magnetic nail sweeper's compact and lightweight design makes the sweeping can be done anywhere you want, Push or pull it under the furniture, passing through the workshop floor, driveway, mud, grass, and gravel.
- Cambridge Assessment: 96 individual valves were configured with detection, flush, hygiene and cleaner settings, illustrating the level of commissioning detail a large retrofit can require.
- National Exhibition Centre: The case selected room-level Sensazone controls where the number of individual units made separate installation a significant initial investment.
- Clearwater Court, Reading: Cistermiser reports a 90.7% reduction in urinal water use during a Thames Water trial. The washroom package also included sensor taps and toilets from another supplier, so the combined result cannot be assigned solely to Direct Flush.
- bet365 UK head office: Cistermiser presents an 85% headline reduction in water waste. The page describes the trial dates and design, but the opened case text does not provide the underlying measurement series; treat the figure as a manufacturer-reported headline.
- University of Surrey: The 32,525,000-litre annual figure and 140-day average return relate to the university’s wider programme and its occupancy context. They should not be copied into a commercial-building business case without a measured baseline.
How can you verify that a retrofit is delivering?
Agree the verification method before installation. Use the same meter or sub-meter, comparable occupancy periods and a documented tariff. Compare litres per occupied day, litres per visitor or another measure that reflects how the building is used; a raw monthly total can fall simply because a site is closed.
Check that the new system is actually responding to use. During commissioning, confirm a user-triggered flush, the programmed hygiene cycle, the cleaner’s mode, recovery after a power interruption and the response when the washroom is empty. Record the final settings and retain the baseline readings, invoices and occupancy notes. If savings are below expectation, inspect for a bypassed cistern, a failed sensor, an excessive timeout, a leaking valve or another fixture on the same meter.
Independent reader supportYour contribution helps us test, update, and keep practical guides available for everyone.What should a construction or facilities specification include?
Write measurable requirements rather than naming a control type alone. Specify the fixture count, expected occupancy profile, permitted flush volume or range, detection and timeout settings, hygiene-flush capability, cleaner override, power and isolation arrangements, access for maintenance, commissioning records and handover training. Require the installer to confirm compatibility with the existing bowls, pipework, pressure and drainage.
For a refurbishment, coordinate the work with ceiling access, electrical containment, waterproofing and planned washroom shutdowns. For a new build, decide early whether individual valves, a group-control architecture or waterless fixtures best fit the drainage and maintenance strategy. In either case, have a qualified installer verify local plumbing requirements and the final configuration.
What are the most common failure modes?
- Assuming every flush is caused by users: A clock-driven cistern can run all night. Prove the meter pattern.
- Using an old tariff in the business case: Historical £ figures from Thames Water or a manufacturer catalogue are not today’s prices. Recalculate with current supply and sewer charges.
- Ignoring low-use hygiene: Demand control still needs an appropriate periodic-flush policy.
- Choosing individual valves without access planning: Large fixture counts can make wiring, power supplies and future maintenance expensive.
- Attributing package savings to one product: Sensor taps, toilets, occupancy changes and other measures can influence a case-study result.
- Leaving the timer active in parallel: A bypass or legacy cistern controller can continue flushing after a new sensor is installed. Include isolation and commissioning checks.
What is the practical decision?
Uncontrolled urinal flushing is primarily a controls-and-verification problem. Measure the out-of-hours demand, identify the equipment creating it, and select the least disruptive control that matches occupancy and hygiene needs. Individual PIR valves provide fixture-level response; room or group controls can be more economical for large washrooms; a revised timer is only a limited compromise; and waterless urinals belong in projects that can support their drainage, cleaning and acceptance requirements.
Also popular on Amazon
- APPLY TO MOST DRILLS : 6 pieces screw extractors work with any drill and all the screw size or bolt (3-12mm), These extractor tools are used to reverse the damaged screw counterclockwise until it is released
- The DIY Tools for Men-Men won't know they need screw extractor set until they have one! This screw extractor set is GIFTS WRAP AVAILABLE, can be gifted to your loved ones as it reflects a fresh trend with fun and practical. Amazing and Unique tool gifts for men women. The must have stocking stuffers for men, gifts for dad, husband, father, him, guy teens, adult, Boyfriend, son on Birthdays, Christmas, Fathers Day or anniversary. Perfect Holiday Gifts Guide
- HIGH QUALITY - This damaged screw remover tool kit is made from High-Speed Steel H.S.S 4341# , which have high hardness of 63hrc, it's durable and easily to remove any damaged screws.
- EASY TO USE: Just two simple steps to get the job done - drill a hole with a cutting size using the right size screw extractor and easily remove the screw or bolt using the removal tool Hardness 63-65HRC: Titanium hardened steel material, more durable than most screw extractors on the market, better hardness and durability than others, buy with confidence and complete peace of mind
- Cool Gadgets for Men Dad Christmas Birthday Gifts for Men and Women - Men won't know they need screw extractor sets until they have one! Every screw has the potential to rust and break, which can create a situation where it cannot be removed. Owning it, there will be no anxiety about rusty screws. This screw extractor set is GIFTS WRAP AVAILABLE, can be gifted to your loved ones as it reflects a fresh trend with fun and practical. Amazing and unique tool gifts for men women. A must have stocking stuffer for men on birthdays, Christmas, Father's Day or anniversaries, a gifts for dads, husbands, fathers, him, adults, boyfriends, sons. The best and most practical and surprising Christmas gifts
Use published figures to challenge the assumption that the waste is minor, not to promise a generic percentage. A current meter baseline, a current tariff and a documented maintenance plan will produce a more defensible water-efficiency decision than any headline saving.
Frequently Asked Questions
Why can’t a cleaning or staff campaign stop urinal water waste?
A campaign may change user behaviour, but it cannot stop a timer-driven cistern from flushing an empty washroom. Controls are needed to make flushing depend on use or a deliberately managed occupancy and hygiene schedule.
Windows Errors? Fix Them Before They Spread
Repair common Windows errors and clear accumulated junk for a smoother, more stable PC - no reinstall needed.Free scan · no reinstallCrashes, No Sound, or Screen Glitches?
Random freezes, missing sound and display glitches usually trace back to one bad driver. Find and replace yours safely.Free scan · under a minuteCan PIR urinal controls be used in a washroom that closes for long periods?
They can, provided the system includes an appropriate periodic hygiene flush and the interval is approved within the site’s water-safety and maintenance arrangements. Long closures should be documented in the operating plan rather than handled by leaving a normal timer running.
What information should an installer receive before quoting?
Provide fixture and cistern counts, a plumbing schematic or survey, pressure and electrical information, occupancy and closure schedules, meter data, access restrictions and the required cleaning and hygiene procedures. This allows the installer to price isolation, wiring, making-good and commissioning rather than only the control hardware.
How do I tell whether savings came from the urinal controls?
Use the same meter or sub-meter, compare equivalent occupancy periods and record other changes such as tap, toilet or HVAC work. Where possible, isolate the urinal branch during diagnosis and retain commissioning settings so a later review can distinguish control performance from occupancy effects.